Loading...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 | Mylex DAC960/DAC1100 PCI RAID Controller Driver for Linux
Version 2.2.4 for Linux 2.2.11
Version 2.0.4 for Linux 2.0.37
PRODUCTION RELEASE
23 August 1999
Leonard N. Zubkoff
Dandelion Digital
lnz@dandelion.com
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
INTRODUCTION
Mylex, Inc. designs and manufactures a variety of high performance PCI RAID
controllers. Mylex Corporation is located at 34551 Ardenwood Blvd., Fremont,
California 94555, USA and can be reached at 510/796-6100 or on the World Wide
Web at http://www.mylex.com. Mylex RAID Technical Support can be reached by
electronic mail at support@mylex.com (for eXtremeRAID 1100 and older DAC960
models) or techsup@mylex.com (for AcceleRAID models), by voice at 510/608-2400,
or by FAX at 510/745-7715. Contact information for offices in Europe and Japan
is available on the Web site.
The latest information on Linux support for DAC960 PCI RAID Controllers, as
well as the most recent release of this driver, will always be available from
my Linux Home Page at URL "http://www.dandelion.com/Linux/". The Linux DAC960
driver supports all current DAC960 PCI family controllers including the
AcceleRAID models, as well as the eXtremeRAID 1100; see below for a complete
list. For simplicity, in most places this documentation refers to DAC960
generically rather than explicitly listing all the models.
Bug reports should be sent via electronic mail to "lnz@dandelion.com". Please
include with the bug report the complete configuration messages reported by the
driver at startup, along with any subsequent system messages relevant to the
controller's operation, and a detailed description of your system's hardware
configuration.
Please consult the DAC960 RAID controller documentation for detailed
information regarding installation and configuration of the controllers. This
document primarily provides information specific to the Linux DAC960 support.
DRIVER FEATURES
The DAC960 RAID controllers are supported solely as high performance RAID
controllers, not as interfaces to arbitrary SCSI devices. The Linux DAC960
driver operates at the block device level, the same level as the SCSI and IDE
drivers. Unlike other RAID controllers currently supported on Linux, the
DAC960 driver is not dependent on the SCSI subsystem, and hence avoids all the
complexity and unnecessary code that would be associated with an implementation
as a SCSI driver. The DAC960 driver is designed for as high a performance as
possible with no compromises or extra code for compatibility with lower
performance devices. The DAC960 driver includes extensive error logging and
online configuration management capabilities. Except for initial configuration
of the controller and adding new disk drives, most everything can be handled
from Linux while the system is operational.
The DAC960 driver is architected to support up to 8 controllers per system.
Each DAC960 controller can support up to 15 disk drives per channel, for a
maximum of 45 drives on a three channel controller. The drives installed on a
controller are divided into one or more "Drive Groups", and then each Drive
Group is subdivided further into 1 to 32 "Logical Drives". Each Logical Drive
has a specific RAID Level and caching policy associated with it, and it appears
to Linux as a single block device. Logical Drives are further subdivided into
up to 7 partitions through the normal Linux and PC disk partitioning schemes.
Logical Drives are also known as "System Drives", and Drive Groups are also
called "Packs". Both terms are in use in the Mylex documentation; I have
chosen to standardize on the more generic "Logical Drive" and "Drive Group".
DAC960 RAID disk devices are named in the style of the Device File System
(DEVFS). The device corresponding to Logical Drive D on Controller C is
referred to as /dev/rd/cCdD, and the partitions are called /dev/rd/cCdDp1
through /dev/rd/cCdDp7. For example, partition 3 of Logical Drive 5 on
Controller 2 is referred to as /dev/rd/c2d5p3. Note that unlike with SCSI
disks the device names will not change in the event of a disk drive failure.
The DAC960 driver is assigned major numbers 48 - 55 with one major number per
controller. The 8 bits of minor number are divided into 5 bits for the Logical
Drive and 3 bits for the partition.
SUPPORTED DAC960/DAC1100 PCI RAID CONTROLLERS
The following list comprises the supported DAC960 and DAC1100 PCI RAID
Controllers as of the date of this document. It is recommended that anyone
purchasing a Mylex PCI RAID Controller not in the following table contact the
author beforehand to verify that it is or will be supported.
eXtremeRAID 1100 (DAC1164P)
3 Wide Ultra-2/LVD SCSI channels
233MHz StrongARM SA 110 Processor
64 Bit PCI (backward compatible with 32 Bit PCI slots)
16MB/32MB/64MB Parity SDRAM Memory with Battery Backup
AcceleRAID 250 (DAC960PTL1)
Uses onboard Symbios SCSI chips on certain motherboards
Also includes one onboard Wide Ultra-2/LVD SCSI Channel
66MHz Intel i960RD RISC Processor
4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
AcceleRAID 200 (DAC960PTL0)
Uses onboard Symbios SCSI chips on certain motherboards
Includes no onboard SCSI Channels
66MHz Intel i960RD RISC Processor
4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
AcceleRAID 150 (DAC960PRL)
Uses onboard Symbios SCSI chips on certain motherboards
Also includes one onboard Wide Ultra-2/LVD SCSI Channel
33MHz Intel i960RP RISC Processor
4MB Parity EDO Memory
DAC960PJ 1/2/3 Wide Ultra SCSI-3 Channels
66MHz Intel i960RD RISC Processor
4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
DAC960PG 1/2/3 Wide Ultra SCSI-3 Channels
33MHz Intel i960RP RISC Processor
4MB/8MB ECC EDO Memory
DAC960PU 1/2/3 Wide Ultra SCSI-3 Channels
Intel i960CF RISC Processor
4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory
DAC960PD 1/2/3 Wide Fast SCSI-2 Channels
Intel i960CF RISC Processor
4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory
DAC960PL 1/2/3 Wide Fast SCSI-2 Channels
Intel i960 RISC Processor
2MB/4MB/8MB/16MB/32MB DRAM Memory
For the eXtremeRAID 1100, firmware version 5.06-0-52 or above is required.
For the AcceleRAID 250, 200, and 150, firmware version 4.06-0-57 or above is
required.
For the DAC960PJ and DAC960PG, firmware version 4.06-0-00 or above is required.
For the DAC960PU, DAC960PD, and DAC960PL, firmware version 3.51-0-04 or above
is required.
Note that earlier revisions of the DAC960PU, DAC960PD, and DAC960PL controllers
were delivered with version 2.xx firmware. Version 2.xx firmware is not
supported by this driver and no support is envisioned. Contact Mylex RAID
Technical Support to inquire about upgrading controllers with version 2.xx
firmware to version 3.51-0-04. Upgrading to version 3.xx firmware requires
installation of higher capacity Flash ROM chips, and not all DAC960PD and
DAC960PL controllers can be upgraded.
Please note that not all SCSI disk drives are suitable for use with DAC960
controllers, and only particular firmware versions of any given model may
actually function correctly. Similarly, not all motherboards have a BIOS that
properly initializes the AcceleRAID 250, AcceleRAID 200, AcceleRAID 150,
DAC960PJ, and DAC960PG because the Intel i960RD/RP is a multi-function device.
If in doubt, contact Mylex RAID Technical Support (support@mylex.com) to verify
compatibility. Mylex makes available a hard disk compatibility list by FTP at
ftp://ftp.mylex.com/pub/dac960/diskcomp.html.
DRIVER INSTALLATION
This distribution was prepared for Linux kernel version 2.2.11 or 2.0.37.
To install the DAC960 RAID driver, you may use the following commands,
replacing "/usr/src" with wherever you keep your Linux kernel source tree:
cd /usr/src
tar -xvzf DAC960-2.2.4.tar.gz (or DAC960-2.0.4.tar.gz)
mv README.DAC960 linux/Documentation
mv DAC960.[ch] linux/drivers/block
patch -p0 < DAC960.patch
cd linux
make config
make depend
make bzImage (or zImage)
Then install "arch/i386/boot/bzImage" or "arch/i386/boot/zImage" as your
standard kernel, run lilo if appropriate, and reboot.
To create the necessary devices in /dev, the "make_rd" script included in
"DAC960-Utilities.tar.gz" from http://www.dandelion.com/Linux/ may be used.
LILO 21 and FDISK v2.9 include DAC960 support; also included in this archive
are patches to LILO 20 and FDISK v2.8 that add DAC960 support, along with
statically linked executables of LILO and FDISK. This modified version of LILO
will allow booting from a DAC960 controller and/or mounting the root file
system from a DAC960.
Red Hat Linux 6.0 and SuSE Linux 6.1 include support for Mylex PCI RAID
controllers. Installing directly onto a DAC960 may be problematic from other
Linux distributions until their installation utilities are updated.
INSTALLATION NOTES
Before installing Linux or adding DAC960 logical drives to an existing Linux
system, the controller must first be configured to provide one or more logical
drives using the BIOS Configuration Utility or DACCF. Please note that since
there are only at most 6 usable partitions on each logical drive, systems
requiring more partitions should subdivide a drive group into multiple logical
drives, each of which can have up to 6 partitions. Also, note that with large
disk arrays it is advisable to enable the 8GB BIOS Geometry (255/63) rather
than accepting the default 2GB BIOS Geometry (128/32); failing to so do will
cause the logical drive geometry to have more than 65535 cylinders which will
make it impossible for FDISK to be used properly. The 8GB BIOS Geometry can be
enabled by configuring the DAC960 BIOS, which is accessible via Alt-M during
the BIOS initialization sequence.
For maximum performance and the most efficient E2FSCK performance, it is
recommended that EXT2 file systems be built with a 4KB block size and 16 block
stride to match the DAC960 controller's 64KB default stripe size. The command
"mke2fs -b 4096 -R stride=16 <device>" is appropriate. Unless there will be a
large number of small files on the file systems, it is also beneficial to add
the "-i 16384" option to increase the bytes per inode parameter thereby
reducing the file system metadata. Finally, on systems that will only be run
with Linux 2.2 or later kernels it is beneficial to enable sparse superblocks
with the "-s 1" option.
DAC960 ANNOUNCEMENTS MAILING LIST
The DAC960 Announcements Mailing List provides a forum for informing Linux
users of new driver releases and other announcements regarding Linux support
for DAC960 PCI RAID Controllers. To join the mailing list, send a message to
"dac960-announce-request@dandelion.com" with the line "subscribe" in the
message body.
CONTROLLER CONFIGURATION AND STATUS MONITORING
The DAC960 RAID controllers running firmware 4.06 or above include a Background
Initialization facility so that system downtime is minimized both for initial
installation and subsequent configuration of additional storage. The BIOS
Configuration Utility (accessible via Alt-R during the BIOS initialization
sequence) is used to quickly configure the controller, and then the logical
drives that have been created are available for immediate use even while they
are still being initialized by the controller. The primary need for online
configuration and status monitoring is then to avoid system downtime when disk
drives fail and must be replaced. Mylex's online monitoring and configuration
utilities are being ported to Linux and will become available at some point in
the future. Note that with a SAF-TE (SCSI Accessed Fault-Tolerant Enclosure)
enclosure, the controller is able to rebuild failed drives automatically as
soon as a drive replacement is made available.
The primary interfaces for controller configuration and status monitoring are
special files created in the /proc/rd/... hierarchy along with the normal
system console logging mechanism. Whenever the system is operating, the DAC960
driver queries each controller for status information every 10 seconds, and
checks for additional conditions every 60 seconds. The initial status of each
controller is always available for controller N in /proc/rd/cN/initial_status,
and the current status as of the last status monitoring query is available in
/proc/rd/cN/current_status. In addition, status changes are also logged by the
driver to the system console and will appear in the log files maintained by
syslog. The progress of asynchronous rebuild or consistency check operations
is also available in /proc/rd/cN/current_status, and progress messages are
logged to the system console at most every 60 seconds.
Starting with the 2.2.3/2.0.3 versions of the driver, the status information
available in /proc/rd/cN/initial_status and /proc/rd/cN/current_status has been
augmented to include the vendor, model, revision, and serial number (if
available) for each physical device found connected to the controller:
***** DAC960 RAID Driver Version 2.2.3 of 19 August 1999 *****
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
Configuring Mylex DAC960PRL PCI RAID Controller
Firmware Version: 4.07-0-07, Channels: 1, Memory Size: 16MB
PCI Bus: 1, Device: 4, Function: 1, I/O Address: Unassigned
PCI Address: 0xFE300000 mapped at 0xA0800000, IRQ Channel: 21
Controller Queue Depth: 128, Maximum Blocks per Command: 128
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
SAF-TE Enclosure Management Enabled
Physical Devices:
0:0 Vendor: IBM Model: DRVS09D Revision: 0270
Serial Number: 68016775HA
Disk Status: Online, 17928192 blocks
0:1 Vendor: IBM Model: DRVS09D Revision: 0270
Serial Number: 68004E53HA
Disk Status: Online, 17928192 blocks
0:2 Vendor: IBM Model: DRVS09D Revision: 0270
Serial Number: 13013935HA
Disk Status: Online, 17928192 blocks
0:3 Vendor: IBM Model: DRVS09D Revision: 0270
Serial Number: 13016897HA
Disk Status: Online, 17928192 blocks
0:4 Vendor: IBM Model: DRVS09D Revision: 0270
Serial Number: 68019905HA
Disk Status: Online, 17928192 blocks
0:5 Vendor: IBM Model: DRVS09D Revision: 0270
Serial Number: 68012753HA
Disk Status: Online, 17928192 blocks
0:6 Vendor: ESG-SHV Model: SCA HSBP M6 Revision: 0.61
Logical Drives:
/dev/rd/c0d0: RAID-5, Online, 89640960 blocks, Write Thru
No Rebuild or Consistency Check in Progress
To simplify the monitoring process for custom software, the special file
/proc/rd/status returns "OK" when all DAC960 controllers in the system are
operating normally and no failures have occurred, or "ALERT" if any logical
drives are offline or critical or any non-standby physical drives are dead.
Configuration commands for controller N are available via the special file
/proc/rd/cN/user_command. A human readable command can be written to this
special file to initiate a configuration operation, and the results of the
operation can then be read back from the special file in addition to being
logged to the system console. The shell command sequence
echo "<configuration-command>" > /proc/rd/c0/user_command
cat /proc/rd/c0/user_command
is typically used to execute configuration commands. The configuration
commands are:
flush-cache
The "flush-cache" command flushes the controller's cache. The system
automatically flushes the cache at shutdown or if the driver module is
unloaded, so this command is only needed to be certain a write back cache
is flushed to disk before the system is powered off by a command to a UPS.
Note that the flush-cache command also stops an asynchronous rebuild or
consistency check, so it should not be used except when the system is being
halted.
kill <channel>:<target-id>
The "kill" command marks the physical drive <channel>:<target-id> as DEAD.
This command is provided primarily for testing, and should not be used
during normal system operation.
make-online <channel>:<target-id>
The "make-online" command changes the physical drive <channel>:<target-id>
from status DEAD to status ONLINE. In cases where multiple physical drives
have been killed simultaneously, this command may be used to bring them
back online, after which a consistency check is advisable.
Warning: make-online should only be used on a dead physical drive that is
an active part of a drive group, never on a standby drive.
make-standby <channel>:<target-id>
The "make-standby" command changes physical drive <channel>:<target-id>
from status DEAD to status STANDBY. It should only be used in cases where
a dead drive was replaced after an automatic rebuild was performed onto a
standby drive. It cannot be used to add a standby drive to the controller
configuration if one was not created initially; the BIOS Configuration
Utility must be used for that currently.
rebuild <channel>:<target-id>
The "rebuild" command initiates an asynchronous rebuild onto physical drive
<channel>:<target-id>. It should only be used when a dead drive has been
replaced.
check-consistency <logical-drive-number>
The "check-consistency" command initiates an asynchronous consistency check
of <logical-drive-number> with automatic restoration. It can be used
whenever it is desired to verify the consistency of the redundancy
information.
cancel-rebuild
cancel-consistency-check
The "cancel-rebuild" and "cancel-consistency-check" commands cancel any
rebuild or consistency check operations previously initiated.
EXAMPLE I - DRIVE FAILURE WITHOUT A STANDBY DRIVE
The following annotated logs demonstrate the controller configuration and and
online status monitoring capabilities of the Linux DAC960 Driver. The test
configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a
DAC960PJ controller. The physical drives are configured into a single drive
group without a standby drive, and the drive group has been configured into two
logical drives, one RAID-5 and one RAID-6. Note that these logs are from an
earlier version of the driver and the messages have changed somewhat with newer
releases, but the functionality remains similar. First, here is the current
status of the RAID configuration:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
Configuring Mylex DAC960PJ PCI RAID Controller
Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
Controller Queue Depth: 128, Maximum Blocks per Command: 128
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Online, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru
No Rebuild or Consistency Check in Progress
gwynedd:/u/lnz# cat /proc/rd/status
OK
The above messages indicate that everything is healthy, and /proc/rd/status
returns "OK" indicating that there are no problems with any DAC960 controller
in the system. For demonstration purposes, while I/O is active Physical Drive
1:1 is now disconnected, simulating a drive failure. The failure is noted by
the driver within 10 seconds of the controller's having detected it, and the
driver logs the following console status messages indicating that Logical
Drives 0 and 1 are now CRITICAL as a result of Physical Drive 1:1 being DEAD:
DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
DAC960#0: Physical Drive 1:1 killed because of timeout on SCSI command
DAC960#0: Physical Drive 1:1 is now DEAD
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL
The Sense Keys logged here are just Check Condition / Unit Attention conditions
arising from a SCSI bus reset that is forced by the controller during its error
recovery procedures. Concurrently with the above, the driver status available
from /proc/rd also reflects the drive failure. The status message in
/proc/rd/status has changed from "OK" to "ALERT":
gwynedd:/u/lnz# cat /proc/rd/status
ALERT
and /proc/rd/c0/current_status has been updated:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Dead, 2201600 blocks
1:2 - Disk: Online, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
No Rebuild or Consistency Check in Progress
Since there are no standby drives configured, the system can continue to access
the logical drives in a performance degraded mode until the failed drive is
replaced and a rebuild operation completed to restore the redundancy of the
logical drives. Once Physical Drive 1:1 is replaced with a properly
functioning drive, or if the physical drive was killed without having failed
(e.g., due to electrical problems on the SCSI bus), the user can instruct the
controller to initiate a rebuild operation onto the newly replaced drive:
gwynedd:/u/lnz# echo "rebuild 1:1" > /proc/rd/c0/user_command
gwynedd:/u/lnz# cat /proc/rd/c0/user_command
Rebuild of Physical Drive 1:1 Initiated
The echo command instructs the controller to initiate an asynchronous rebuild
operation onto Physical Drive 1:1, and the status message that results from the
operation is then available for reading from /proc/rd/c0/user_command, as well
as being logged to the console by the driver.
Within 10 seconds of this command the driver logs the initiation of the
asynchronous rebuild operation:
DAC960#0: Rebuild of Physical Drive 1:1 Initiated
DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01
DAC960#0: Physical Drive 1:1 is now WRITE-ONLY
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 1% completed
and /proc/rd/c0/current_status is updated:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Write-Only, 2201600 blocks
1:2 - Disk: Online, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 6% completed
As the rebuild progresses, the current status in /proc/rd/c0/current_status is
updated every 10 seconds:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Write-Only, 2201600 blocks
1:2 - Disk: Online, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 15% completed
and every minute a progress message is logged to the console by the driver:
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 32% completed
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 63% completed
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 94% completed
DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 94% completed
Finally, the rebuild completes successfully. The driver logs the status of the
logical and physical drives and the rebuild completion:
DAC960#0: Rebuild Completed Successfully
DAC960#0: Physical Drive 1:1 is now ONLINE
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE
/proc/rd/c0/current_status is updated:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Online, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru
Rebuild Completed Successfully
and /proc/rd/status indicates that everything is healthy once again:
gwynedd:/u/lnz# cat /proc/rd/status
OK
EXAMPLE II - DRIVE FAILURE WITH A STANDBY DRIVE
The following annotated logs demonstrate the controller configuration and and
online status monitoring capabilities of the Linux DAC960 Driver. The test
configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a
DAC960PJ controller. The physical drives are configured into a single drive
group with a standby drive, and the drive group has been configured into two
logical drives, one RAID-5 and one RAID-6. Note that these logs are from an
earlier version of the driver and the messages have changed somewhat with newer
releases, but the functionality remains similar. First, here is the current
status of the RAID configuration:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
Configuring Mylex DAC960PJ PCI RAID Controller
Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
Controller Queue Depth: 128, Maximum Blocks per Command: 128
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Online, 2201600 blocks
1:3 - Disk: Standby, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
No Rebuild or Consistency Check in Progress
gwynedd:/u/lnz# cat /proc/rd/status
OK
The above messages indicate that everything is healthy, and /proc/rd/status
returns "OK" indicating that there are no problems with any DAC960 controller
in the system. For demonstration purposes, while I/O is active Physical Drive
1:2 is now disconnected, simulating a drive failure. The failure is noted by
the driver within 10 seconds of the controller's having detected it, and the
driver logs the following console status messages:
DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
DAC960#0: Physical Drive 1:2 killed because of timeout on SCSI command
DAC960#0: Physical Drive 1:2 is now DEAD
DAC960#0: Physical Drive 1:2 killed because it was removed
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL
Since a standby drive is configured, the controller automatically begins
rebuilding onto the standby drive:
DAC960#0: Physical Drive 1:3 is now WRITE-ONLY
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed
Concurrently with the above, the driver status available from /proc/rd also
reflects the drive failure and automatic rebuild. The status message in
/proc/rd/status has changed from "OK" to "ALERT":
gwynedd:/u/lnz# cat /proc/rd/status
ALERT
and /proc/rd/c0/current_status has been updated:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Dead, 2201600 blocks
1:3 - Disk: Write-Only, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed
As the rebuild progresses, the current status in /proc/rd/c0/current_status is
updated every 10 seconds:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Dead, 2201600 blocks
1:3 - Disk: Write-Only, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed
and every minute a progress message is logged on the console by the driver:
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 76% completed
DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 66% completed
DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 84% completed
Finally, the rebuild completes successfully. The driver logs the status of the
logical and physical drives and the rebuild completion:
DAC960#0: Rebuild Completed Successfully
DAC960#0: Physical Drive 1:3 is now ONLINE
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE
/proc/rd/c0/current_status is updated:
***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
Configuring Mylex DAC960PJ PCI RAID Controller
Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
Controller Queue Depth: 128, Maximum Blocks per Command: 128
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Dead, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
Rebuild Completed Successfully
and /proc/rd/status indicates that everything is healthy once again:
gwynedd:/u/lnz# cat /proc/rd/status
OK
Note that the absence of a viable standby drive does not create an "ALERT"
status. Once dead Physical Drive 1:2 has been replaced, the controller must be
told that this has occurred and that the newly replaced drive should become the
new standby drive:
gwynedd:/u/lnz# echo "make-standby 1:2" > /proc/rd/c0/user_command
gwynedd:/u/lnz# cat /proc/rd/c0/user_command
Make Standby of Physical Drive 1:2 Succeeded
The echo command instructs the controller to make Physical Drive 1:2 into a
standby drive, and the status message that results from the operation is then
available for reading from /proc/rd/c0/user_command, as well as being logged to
the console by the driver. Within 60 seconds of this command the driver logs:
DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01
DAC960#0: Physical Drive 1:2 is now STANDBY
DAC960#0: Make Standby of Physical Drive 1:2 Succeeded
and /proc/rd/c0/current_status is updated:
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
...
Physical Devices:
0:1 - Disk: Online, 2201600 blocks
0:2 - Disk: Online, 2201600 blocks
0:3 - Disk: Online, 2201600 blocks
1:1 - Disk: Online, 2201600 blocks
1:2 - Disk: Standby, 2201600 blocks
1:3 - Disk: Online, 2201600 blocks
Logical Drives:
/dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
/dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
Rebuild Completed Successfully
|